Infant Intensive Care System AIr-ShIeldS® IICS-90 MT-1779-2005. H08-2002A 02 Performance across the range. Sims 4 for mac using utorrent. Infant Intensive Care System IICS-90 Capable of providing any configuration to meet. Control modes Skin Mode and Manual Mode (0-100% in 25% increments) Skin mode control range 34.0˚ C. Controlled mode and manual control mode. The mode selected is shown by a green illuminated SKIN or MANUAL indicator. The Air-Shields llCS-90 is a servo-controlled infant radiant warmer that incorporates a tiltable bassinet, an overhead radiant heater module, the control unit and control panel. These are supported by a column. Air-Shields IICS-90 (Infant Intensive Care System) The warming module head can be moved 65˚ in either direction to facilitate other procedures such as x-ray, without interrupting thermal operation. All bassinets include a smooth operating mattress tilt. An organizer panel at the rear of the bassinet supports efficient cable management. COPYRIGHT@3 1998, HILL-ROM AIR-SHIELDS, INC. TcPC02 probe. To avoid overheating the skin, the location of the skin temperature probe must be such that the skin around the Sensor is in direct line with the radiation from the warmer. Do not place anything between the radiant warmer and the infant that will interfere with the radiation from the.
One moment please.
Not A Member?Sign Up
- Videos
- News
DESCRIPTION
Infant Warmer
Infant warmer with dual function controller for both skin servo and manual heat control. The unit features an alarm system, a large display and optimum illumination.
FORUMSView All (2)
Air Shields Iics 90 Service Manual Pdf
![Air shields iics-90 service manual Air shields iics-90 service manual](https://images.dotmed.com/images/listingpics/1035559.jpg)
0Replies5 years ago | 5 years agomattress Massey ferguson 1428 manual. https://hereyfil513.weebly.com/resident-evil-3-download.html. Do you have any mattresses for the Air Shields IICS-90 PM 78-1 infant warmer? We are needing to purchase one. Jonie OB Team Lead Integris Bass Baptist HC, Enid, OK Reply |
-CharlesA 6 years ago | 6 years agoservice manual air shields PM78-1 infant warmer Greetings! It will very helpfull if someone have the service manual for a PM78-1 infant warmer. https://ameblo.jp/colholzbeadreo1973/entry-12634646031.html. Thanks. Eyebeam for mac free. Reply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Infant Incubators & Warmers Companies
FEATURES
- Easy x-ray access with its conveniently located x-cassette trays provides minimum disturbance to the patient
- Comprehensive alarm system
SPECIFICATIONS
Height | 76 in |
Length | 43 in |
Weight | 185 lbs |
Width | 28 in |
FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies
MFG SKU | NSN | Item Name | Details | CAGE Code | RFQ |
---|---|---|---|---|---|
7807380CC | 6515-01-415-7438 | Infant Intensive Care System | Special Features: Gelectrical characteristics: 110/220 vac, 50/60 hz. a customer order list is available for accessories not listed herein. contact dpsc-mq dsn 444-5978 or (215) 737-5978. contract no. SP0200-95-D-8707. General Characteristics Item Description: Includes the following components: a mattress 29.8 in. long X 23.5 in. wide, 1 ea; warmer module 34.0 in. long X 12.0 in. wide, 1 ea; 100 watt exam light illumination; thumbwheel type, led display, skin set temp. gage with 0.1 C resolution; 15 min. manual heat timer; alarms: automatic test, power and probe fail, and low skin/high skin (-0.5 C/+0.5 c); manuals included: installation instructions, 2 ea; operator/user manual, 2 ea; maintenance/service manual, 2 ea; parts price list, 2 ea; wiring schematics/diagrams, 2 ea. Part Name Assigned BY Controlling Agency: Infant intensive care system 110/220 vac 50/60HZ | 2A614 | |
IICS-90 IICS90 | 6515-01-415-7438 | Infant Intensive Care System | Special Features: Gelectrical characteristics: 110/220 vac, 50/60 hz. a customer order list is available for accessories not listed herein. contact dpsc-mq dsn 444-5978 or (215) 737-5978. contract no. SP0200-95-D-8707. General Characteristics Item Description: Includes the following components: a mattress 29.8 in. long X 23.5 in. wide, 1 ea; warmer module 34.0 in. long X 12.0 in. wide, 1 ea; 100 watt exam light illumination; thumbwheel type, led display, skin set temp. gage with 0.1 C resolution; 15 min. manual heat timer; alarms: automatic test, power and probe fail, and low skin/high skin (-0.5 C/+0.5 c); manuals included: installation instructions, 2 ea; operator/user manual, 2 ea; maintenance/service manual, 2 ea; parts price list, 2 ea; wiring schematics/diagrams, 2 ea. Part Name Assigned BY Controlling Agency: Infant intensive care system 110/220 vac 50/60HZ | 2A614 | |
0120100 | 6515-00-967-5548 | Nebulizer | 2A614 | ||
68 209 20 6820920 | 6515-01-493-7028 | Probe, Incubator | General Characteristics Item Description: Unit package quantity - 10 End Item Identification: Incubator, air shields vickers | 2A614 | |
6820970 | 6515-01-510-0500 | Probe, Skin | Part Name Assigned BY Controlling Agency: Reuseable baby skin probe End Item Identification: C100/200 incubator | 2A614 | |
12-615-00 1261500 | 6515-01-351-0942 | Sleeve, Incubator, Iris | General Characteristics Item Description: Reusable; for use with infant incubator, mdl C77 and C86 Part Name Assigned BY Controlling Agency: Sleeve incubator iris end item nsn 6530-00-935-1089 for infant End Item Identification: 6530-00-935-1089 | 2A614 | |
2692070 | 6515-00-868-6810 | Sleeve, Incubator, Iris | General Characteristics Item Description: Plastic, sterile, disposable; 3 packages of 4 sleeves each; unit Qty 12 Part Name Assigned BY Controlling Agency: Sleeve incubator iris plastic sterile disposable 12S | 2A614 | |
45-900-81 4590081 | 6515-00-117-9429 | Suction Apparatus, Surgical | Special Features: Controlled constant or intermittent suction Accessory Components and Quantity: Bag, surgical suction apparatus, 1; cable assembly, power, 1; tube, drainage, plastic, 3/16 in. id, 6 ft lg, 1 Current Type: AC | 2A614 | |
0100075 | 6515-00-381-9105 | Tent, Oxygen and Humidity Therapy | Special Features: Pediatric use; supplies high humidity and aerosol therapy W/or W/out detergents, nebulization therapy W/antibiotics and oxygen therapy W/normal humidity; ice cooled; for pressure regulator order 6680-01-174-6276 and for hood 6515-00-104-8395 Features Provided: Transparent Unit Package Quantity: 1 | 2A614 | |
79 801 25# 7980125 | 6515-01-153-5095 | Tube Uterine Surg a | General Characteristics Item Description: Tube uterine surg aspir plas disp cl 1/2 in id 6 1/2FT lg 25S sterile. individually packed Part Name Assigned BY Controlling Agency: Tube uterine surg aspir plas disp cl 1/2 in id 6 1/2FT lg 25S | 2A614 |
Air Shields Iics-90 Service Manual
FSC 6530 Hospital Furniture, Equipment, Utensils, and Supplies
Air Shields Iics-90 Service Manual
MFG SKU | NSN | Item Name | Details | CAGE Code | RFQ |
---|---|---|---|---|---|
45-920-70 4592070 | 6530-00-257-0119 | Bag, Suction Collection | General Characteristics Item Description: Oplastic, sterile, disposable, 2000 ml. capacity, calibrated windows in 20 ml. increments from 0 to 400 ml., ain 100 ml. increments from 400 to 2000 ml., with tubing 72 inches in length, and capped pouring spout, 25 per box | 2A614 | |
26-200-70 2620070 | 6530-00-466-0457 | Fill Pipe Assembly, | Part Name Assigned BY Controlling Agency: Fill pipe assembly infant incubator humidity reservoir | 2A614 | |
12-360-00 1236000 | 6530-01-107-2671 | Filter, Disc | 2A614 | ||
26-926-73 2692673 | 6530-01-107-2669 | Heater Element | 2A614 | ||
78-902-70 7890270 | 6530-00-149-1961 | Heating Element, Hospital Equipme | General Characteristics Item Description: 7 tubular, stepped body style; 10.5 in. O/al; 0.62 in. od; 9.5 in. lg; far infrared; iron alloy resistance wire quartz sheath material; 120 ac; 60 hertz; single single phase voltage; 560 watts; watt density not rated; 1 element; 5 hermetically sealed stud element connection; 2 terminals; 0.75 in. terminal lg; 1 terminal mtg method; unc stud thread series; 0.138 in. thread size; 32 threads/in. Part Name Assigned BY Controlling Agency: Heating ele hosp equip 120 ac 60 hz sgl sgl phase voltage 560W FSC Application Data: Bassinet, warming | 2A614 | |
78-902-71 7890271 | 6530-00-149-1960 | Heating Element, Hospital Equipme | General Characteristics Item Description: 7 tubular, stepped body style; 10.5 in. O/al; 0.62 in. od; 9.5 in. lg; far infrared; iron alloy resistance wire quartz sheath material; 240 ac; 60 hertz; single single phase voltage; 560 watts; watt density not rated; 1 element; 5 hermetically sealed stud element connection style; 2 terminals; 0.75 in. terminal; 1 terminal mtg method; unc stud thread series designator; 0.138 in. stud thread size; 32 threads/in. Part Name Assigned BY Controlling Agency: Heating ele hosp equip 240 ac 60 hz sgl sgl phase voltage 560W FSC Application Data: Bassinet, warming | 2A614 | |
26-557-70 2655770 | 6530-01-108-2243 | Housing, Thermostat | 2A614 | ||
C 2000 C2000 | 6530-01-505-8238 | Incubator, Infant | Special Features: Front and rear access doors; integrated X-ray tray beneath mattress; low operating sound levels assure supportive environment; visual eye level indicator Material: Plastic Caster Quantity: 4 | 2A614 | |
C-200 WITH COOLING CHAMBER 68-45 C200WITHCOOLINGCHAMBER6845 | 6530-00-935-1089 | Incubator, Infant | Special Features: 9ENAMEL finish cart; water tank humidifier; oxygen inlet in rear; alarms-high air temp, low air temp, high skin temp, low skin temp, temperature sensor failure, power failure and air flow; led temp displays, air/skin; design type chamber; shape rectangular Material: Plastic Overall Width: 46.000 inches nominal | 2A614 | |
C-550 QT C550QT | 6530-01-450-3520 | Incubator, Infant | Special Features: Led air/baby temp, alarms-air/baby temp; probe failure temp, power failure, system failure Overall Length: 23.400 inches nominal Overall Width: 47.000 inches nominal | 2A614 |